Rectifiers

Alpha Cordex 48-3.6kW telecom rectifier modules at the Advanced Technical Services repair depot in Glendale Heights, Illinois

Telecom DC Rectifier Repair for Eltek, Valere, Alpha, Lineage and Emerson

Repair and refurbishment for 48V DC plant rectifiers. Most repairs are returned in 1–2 weeks with a 1-year warranty.

  • 1–2 Week TurnaroundTypical on most repairs
  • 1-Year WarrantyOn most repair services
  • ISO 9001:2015Audited every year
  • Eltek’s NA DepotFor over 20 years

Rectifier brands we repair

Manufacturer names and logos identify the equipment we repair. All trademarks belong to their respective owners.

Eltek and Valere Rectifier Repair from Eltek’s North American Depot

For over 20 years, ATS was Eltek’s North American Depot Repair Center. When Eltek stopped repairing a range of its products in August 2020, ATS was authorized to continue servicing them.

  • The same depot, still repairing them. The depot that handled Eltek’s North American repairs still repairs these modules today, in Glendale Heights, Illinois.
  • Pricing stays consistent with current repair rates.
  • Valere is covered too. Together, Eltek and Valere account for more than 270 of the part numbers on this page.

Flatpack · Flatpack2 · Flatpack2 HE · Smartpack · Powerpack · Nimbus · C-Pug · DCH · TWPP · Valere V-Series and J-Series

Get an Eltek or Valere Repair Quote Continuing support for Eltek customers

Find Your Rectifier Part Number

We repair more than 450 DC plant rectifier, converter and controller part numbers. Search by part number or model, or filter by manufacturer. You can type the part number with or without the dots and dashes.

DC plant rectifier, converter and controller part numbers repaired by Advanced Technical Services, by manufacturer
Manufacturer Model / Part Number Description
Eltek 241113.510 SMPS1000
Eltek 241114.100 Flat Pack
Eltek 241114.112 Flat Pack
Eltek 241114.300 Flat Pack
Eltek 241114.400 Flat Pack
Eltek 241114.401 Flat Pack
Eltek 241114.500 DC to DC
Eltek 241114.501 DC to DC
Eltek 241114.503 DC to DC
Eltek 241114.507 DC to DC
Eltek 241114.800 Flat Pack
Eltek 241115.001 Flat Pack II
Eltek 241115.100 Flat Pack II
Eltek 241115.100.VC Flat Pack
Eltek 241115.100SD Flat Pack
Eltek 241115.105 Flat Pack II HE
Eltek 241115.105.VC Flat Pack II HE
Eltek 241115.110 Flat Pack II
Eltek 241115.110SC Flat Pack II
Eltek 241115.200 Flat Pack II
Eltek 241115.205 Flat Pack II HE
Eltek 241115.205.VC Flat Pack II HE
Eltek 241115.600 Flat Pack II HE
Eltek 241119.100 Flat Pack II
Eltek 241119.105 Flat Pack II HE
Eltek 241119.105.VC Flat Pack II HE
Eltek 241119.905 Nimbus
Eltek 241119.905B Nimbus
Eltek 241240.000 Powerpack
Eltek 241240.020 SMPS4000
Eltek 241246.000 Powerpack
Eltek 241246.000.VC Powerpack
Eltek 241246.100 Powerpack
Eltek 241246.100.VC Powerpack
Eltek 241258.724 VA Limiter
Eltek 241258.732 VA Limiter
Eltek 242100.000 Smart Pak
Eltek 242100.100 Smart Pak
Eltek 242100.110 Smart Pak
Eltek 242100.110.VC Smart Pak
Eltek 242100.111 Smart Pak
Eltek 242100.113 Smart Pak
Eltek 242100.118 Smart Pak
Eltek 242100.118SC Smart Pak
Eltek 30351-000 Brocade
Eltek 30351-100 Brocade
Eltek 30351-200 Brocade
Eltek 30352-100 Brocade
Eltek 30357-200 DCH
Eltek 30360-100 Brocade
Eltek 30361-000 Brocade
Eltek 32004-000 Brocade
Eltek 32005-000 Brocade
Eltek 32006-000 Brocade
Eltek 32007-000 Brocade
Eltek 32008-000 DCH
Eltek 32009-000 DCH
Eltek 32011-000 Brocade
Eltek 32012-000 Brocade
Eltek 32046-000 Brocade
Eltek 32047-000 Brocade
Eltek 32048-000 Brocade
Eltek 32050-000 Brocade
Eltek 32052-000 Brocade
Eltek 380875 Flat Pack II HE 3KW (Cray)
Eltek 502723 TWPP
Eltek 811-0109-0 Mult-Charger
Eltek 811-0206-0 Mult-Charger
Eltek 811-0214-0 Mult-Charger
Eltek 81390393555 Mult-Charger
Eltek 9143100025 Cherokee
Eltek 9155100120 TWPP
Eltek 9155100121 TWPP
Eltek 9155100126 TWPP
Eltek 9155100220 TWPP
Eltek 9155100221 TWPP
Eltek 9155100222 TWPP
Eltek 9155100223 TWPP
Eltek 9155100224 TWPP
Eltek 9155100225 TWPP
Eltek 9155100227 TWPP
Eltek C0050A-VC C-Pug
Eltek C0200A C-Pug
Eltek C0200A-NEBSVC C-Pug
Eltek C0200A-VC C-Pug
Eltek C0350A-VC C-Pug
Eltek C0360A C-Pug
Eltek CA Flat Pack
Eltek DCH0600AB-VV DCH
Eltek DCH0600AB-VV64 DCH
Eltek DCH0600AC-VV DCH
Eltek DCH0600BA-VC DCH
Eltek DCH0600BA-VV DCH
Eltek DCHF1000AA-VV26 DCH
Eltek DCHF1250AC-VB DCH
Eltek 241115.105 FlatPack
Eltek SMPS1000 —
Valere C2500A-FT C2500A Series
Valere DPOEPWRR1250 H Series not side mount
Valere H0500A1-VV H Series not side mount
Valere H0500A1-VV26 H Series not side mount
Valere H0600A1 H Series not side mount
Valere H0600A1-VV26 H Series not side mount
Valere H0750A1 H Series not side mount
Valere H0750A1-VV H Series not side mount
Valere H0750A1-W H Series not side mount
Valere H0750C1-VV H Series not side mount
Valere H0760A1 H Series not side mount
Valere H1000A1 H Series not side mount
Valere H1000A1-VV H Series not side mount
Valere H1000C1-VVR1 H Series not side mount
Valere H1250A1 H Series not side mount
Valere H1250A1-VV H Series not side mount
Valere H1250A1-VVR1 H Series not side mount
Valere H1250B1 H Series not side mount
Valere H1250B1-46CC H Series not side mount
Valere H1250B1-VV H Series not side mount
Valere H1250B1-VV46CC H Series not side mount
Valere H1250C1 H Series not side mount
Valere H1250C1-45 H Series not side mount
Valere H1250C1-VV H Series not side mount
Valere H1250C1-VV45 H Series not side mount
Valere H1250C1-VVCC H Series not side mount
Valere H1500A1 H Series not side mount
Valere H1500A1-VV H Series not side mount
Valere H2000A1 H Series not side mount
Valere H2000A1-37 H Series not side mount
Valere H2000A1-VV H Series not side mount
Valere H2000A1-VV37 H Series not side mount
Valere H2000A1-W H Series not side mount
Valere H2500A1 H Series not side mount
Valere H2500A1-CC H Series not side mount
Valere H2500A1-VV H Series not side mount
Valere H2500A1-VVCC H Series not side mount
Valere H2500A2 H Series not side mount
Valere H2500A2-EX H Series not side mount
Valere H2500A2-VB H Series not side mount
Valere H2500A2-VV H Series not side mount
Valere H2500A2-VVR H Series not side mount
Valere H500A1 H Series not side mount
Valere J0500A1-VC J Series
Valere J0500A1-VV J Series
Valere J0600A1-VC J Series
Valere J0600A1-VV J Series
Valere J0750P1-VV66 J Series
Valere J1000A1-VC J Series
Valere J1000A1-VV J Series
Valere J1200C1-VV J Series
Valere J1500A1 J Series
Valere J1500A1-VC —
Valere JE1250 V-Series
Valere JE2500 V-Series
Valere JF1500 V-Series
Valere L0300A-IW V-Series
Valere L0500B-IW V-Series
Valere L1000A-IW V-Series
Valere L1250A-E4 V-Series
Valere L1250A-IW V-Series
Valere L1250K-IW V-Series
Valere L1500A-IW V-Series
Valere L2000A-IW V-Series
Valere L2500A-E4 V-Series
Valere L2500A-IW V-Series
Valere L3000A-IW V-Series
Valere N0250A-VV V-Series
Valere R241258.724 VA Refurb
Valere S1250C1 S1250C1 Side mount H
Valere S1250C1-VV S1250C1 Side mount H
Valere S30050-K6370-X-1 V-Series
Valere SMR-1000W-48-20 V-Series
Valere SMR-1500W-24-60 V-Series
Valere SMR-1500W-48-30 V-Series
Valere SMR-2000W-48-40 V-Series
Valere SMR-2500W-48-50 V-Series
Valere SMR-500W-48-10 V-Series
Valere TH075012 H Series not side mount
Valere TH120012 H Series not side mount
Valere TH120024 H Series not side mount
Valere TH120048 H Series not side mount
Valere TH200048 H Series not side mount
Valere TH250048 H Series not side mount
Valere TL100024 V-Series
Valere TL100048 V-Series
Valere TL150024 V-Series
Valere TL250048 V-Series
Valere TL50012 V-Series
Valere TL50024 V-Series
Valere TL50048 V-Series
Valere V0250A-IW V-Series
Valere V0250A-VC V-Series
Valere V0250A-VV V-Series
Valere V0250A-VV29 V-Series
Valere V0500A-06 V-Series
Valere V0500A-08 V-Series
Valere V0500A-VC V-Series
Valere V0500A-VV V-Series
Valere V0500A-VV06 V-Series
Valere V0500A-VV26 V-Series
Valere V0500A1-HE V-Series
Valere V0500B-VV V-Series
Valere V0500C-VV V-Series
Valere V0500F-VC V-Series
Valere V0500V1-HE V-Series
Valere V0600A-VV V-Series
Valere V0600B V-Series
Valere V0750A-IWN V-Series
Valere V0750A-VC V-Series
Valere V0750A-VV V-Series
Valere V0750C-VV V-Series
Valere V1000A-VC V-Series
Valere V1000A-VV V-Series
Valere V1000A1-HE V-Series HE
Valere V1000B-VC V-Series
Valere V1000B-VV V-Series
Valere V1000B-VV60 V-Series
Valere V1000B-VVCC V-Series
Valere V1200A-MM V-Series
Valere V1250A-E4 V-Series
Valere V1250A-IW V-Series
Valere V1250A-IWN V-Series
Valere V1250A-MC V-Series
Valere V1250A-MM V-Series
Valere V1250A-OPG V-Series
Valere V1250A-VC V-Series
Valere V1250A-VV V-Series
Valere V1250A-VV11 V-Series
Valere V1250A-VV26 V-Series
Valere V1250A1-HE V-Series HE
Valere V1250B-IW V-Series
Valere V1260A-VV V-Series
Valere V1500A-27 V-Series
Valere V1500A-27R V-Series
Valere V1500A-IW V-Series
Valere V1500A-IWN V-Series
Valere V1500A-MC V-Series
Valere V1500A-MM V-Series
Valere V1500A-VC V-Series
Valere V1500A-VV V-Series
Valere V1500A-VV26 V-Series
Valere V1500A-VV27 V-Series
Valere V1500A-VV27R V-Series
Valere V1500A1-HE V-Series HE
Valere V1500B-AL V-Series
Valere V1500B-E4 V-Series
Valere V1500B-IW V-Series
Valere V1500B-IWN V-Series
Valere V1500B-PCL V-Series
Valere V1500B-VC V-Series
Valere V1500B-VV V-Series
Valere V1800B-IWN V-Series
Valere V2000A-HG V-Series
Valere V2000A-IWN V-Series
Valere V2000A-PCL V-Series
Valere V2000A-VC V-Series
Valere V2000A-VV V-Series
Valere V2000A-VV11 V-Series
Valere V2000A-VV26 V-Series
Valere V2000A1-HE V-Series HE
Valere V2000D-E4 V-Series
Valere V2000D-VV V-Series
Valere V2500A-75 V-Series
Valere V2500A-E4 V-Series
Valere V2500A-IW V-Series
Valere V2500A-MC V-Series
Valere V2500A-MD V-Series
Valere V2500A-MDR V-Series
Valere V2500A-VC V-Series
Valere V2500A-VV V-Series
Valere V2500A-VV11 V-Series
Valere V2500A-VV26 V-Series
Valere V2500A-VV75 V-Series
Valere V2500A1-HE V-Series HE
Valere V3000a-IWN V-Series
Valere V500A-VV V-Series
Valere V500B-VV V-Series
Valere V500C V-Series
Valere v2500a-iwn V-Series
Alpha 010-537-R0-041 —
Alpha 010-548-20 —
Alpha 010-558-20 —
Alpha 010-594-20 —
Alpha 010-594-20-040 —
Alpha (Cordex) 010-623-20-040 —
Alpha (Cordex) 010-600-20-040 48-3.6kW rectifier
Alpha Argus 010-024-20 —
Alpha Argus 010-529-20 —
Alpha Argus 010-546-20 —
Alpha Argus 010-567-20 —
Alpha Argus 010-567-20-040 —
Alpha Argus 010-570-20 —
Alpha Argus 010-570-20-041 —
Alpha Argus 010-572-20-040 —
Alpha Argus 030-716-20-042 Argus Cordex Series Shelf
Alpha Argus CSM 02/012-502-20 —
Alpha Argus 012-548-20 CSM11 PM 24V/48V 1kW DC/DC converter
Alpha Argus 018-574-20-045 Controller
Alpha Argus 012-501-20 DC/DC Converter
Alpha Argus 018-534-20 Intelligent Supervisory Panel 24V SMO2
Alpha Argus 010-539-20-LCD Pathfinder
Alpha Argus 010-547-20 Pathfinder 48V-10Kw Power Module
Alpha Argus 010-562-20 Pathfinder Rectifier
Alpha Argus 010-528-20 RSM 48/10 Rectifier Module
Alpha Argus 018-550-20 RSM 48/10 SUPPLY MODULE
Alpha Argus 010-013-20 RST 24/100 Rectifier
Alpha Argus 010-002-20 RST 48/50 Rectifier
Alpha Argus 010-029-20 Rectifier
Alpha Argus 010-024-20-83 Rectifier Module Case
Alpha Argus (Cordex) 018-574-20 Cordex CXCM4 Control Module
Alpha Cordex 010-571-20 —
GE / OmniOn NE075AC48ATEZ Infinity Rectifier
Alcatel Lucent 300-0669-903-REV-A —
Alcatel Lucent 300-0710-901-REV-U —
Alcatel Lucent 300-0710-902-REV-C —
Alcatel Lucent 300-0713-904-REV-A —
Alcatel Lucent 300-0717-901-REV-T —
Alcatel Lucent 300-0717-903-REV-A —
Alcatel Lucent 3DH03228AJ —
Alcatel Lucent 3DH03236AB —
Alcatel Lucent 408646040 / KS-24510L1A / CPC-A —
Alcatel Lucent 595A2 APU1PS595A2
Alcatel Lucent 595AA APU1PS595AA
Alcatel Lucent 596B3 —
Alcatel Lucent 596B5 —
Alcatel Lucent ES661C 950W Power Rectifier
Alcatel Lucent 632AE Common Power Converter
Alcatel Lucent 107378036 Fan
Alcatel Lucent KS24510L2A / 408646032 / CPC-B —
Alcatel Lucent KS24671L6 —
Alcatel Lucent ES660C Lucent Rectifier Input:120/240VAC Output 48VDC
Alcatel Lucent 644-0327-002 MDR6000 Pwr Amp 6Ghz
Alcatel Lucent 3DH04136AD MDR8000 Power Amplifier
Alcatel Lucent 595A POWER UNIT 380/480 V 65 V
Alcatel Lucent ES460C Rectifier
Alcatel Lucent 494LA S-13 dc to dc power supply converter
Alcatel Lucent (Terayon) NP0800 —
Alcatel Lucent / Tyco 595A3 —
Alcatel Lucent / Tyco 595B2 —
Alcatel Lucent / Tyco 595B3 —
Alcatel Lucent / Tyco 596B4 —
GE 595B APU1PS595B
GE 596D Rectifier
GE (Lineage) CC109159915 596D retrofit carrier
GE (Lineage) CC109160834 NE100AC24ATEZ —
GE (Lineage) NE050AC48 CC109124913
GE (Lineage) NE050AC48ATEZ CC109158878
GE (Tyco / Lucent) 596A2 —
GE (Tyco / Lucent) 596A Rectifier
GE (Tyco) ES760A —
GE / Lineage / Tyco / Lucent 595LTA Rectifier - Featured Model
GE / Lineage / Tyco / Lucent 595LTB —
Peco II (Owned by GE) 24V/100A SM100F24-UP
Peco II (Owned by GE) SM100H24D Delta rectifier
Peco II (Owned by GE) Sl10A120PME Inverter 10 amps
Peco II (Owned by GE) SM100F24PM Rectifier
Peco II (Owned by GE) SM100F48PM —
Peco II (Owned by GE) SM10H48-2PM —
Peco II (Owned by GE) SM50H48D —
Peco II (Owned by GE) SM8H48-1PM —
Tyco QS865A —
Tyco 364A2 Rectifier
Tyco 364A Rectifier SR50/48V
Tyco 597A Shelf
Emerson 1R48500 500W RECTIFIER
Emerson A30B30 486527501
Emerson AP5C56AB —
Emerson AP7C56AE —
Emerson BML440010/1 PBP2BWMDAA (A7000545L) —
Emerson BML440010/1 PBP2BWMDAB (A7000545L) —
Emerson BML440020/1 PBP2BXMDAA (A7000430L) —
Emerson BML440040/1 R48-3500E (1R483500E)
Emerson 486800128 CONVERTER MHSB20A PWPCM40EAA.
Emerson AP7C56BA Controller
Emerson LXP1500 486534204
Emerson LXP1750 486534600
Emerson R48-2000 —
Emerson R48-2000e —
Emerson R48-2000h —
Emerson R48-3500 BML440066/1
Emerson V65/85B50 Rectifier 486533700
Emerson (Candeo) AP5C70AA (A0785070)
Emerson (Candeo) AP5C70AB (A0899131)
Emerson (Candeo) AP5C70AC (A7000745)
Emerson (Candeo) AP5C71CA BML403200/1 PBP2G0YDAA (A0885639L)
Emerson (Candeo) AP5C71DA BML403210/1 (A0885641L)
Emerson (Candeo) LPS200D50 486534000
Emerson (Netsure) LPS200D50 486532602
Emerson (Netsure) 486534001 LPS200D50 208VAC Input
Emerson (Netsure) LPS200E50 486532601
Emerson (Netsure) LPS200E50 (R48-11600) 486532602
Emerson (Netsure) R48-3200 —
Emerson (Netsure) R48-3200E —
Emerson Astec Helios NT5C05CD-61 —
Emerson Astec Helios NT5C06DB S-01 PBPUBTAAAA —
Emerson Astec Helios NT5C06DB S-02 PBPUBTAAAD —
Emerson Astec Helios NT5C06DB S-12 PBPUBTAAAH —
Emerson Astec Helios Nortel NT5C07AA —
Emerson Astec Helios Nortel NT5C07AC —
Emerson Lorain A100B25 Rectifier 486523000
Emerson Lorain A100F25 527404100
Emerson Lorain A25B50 486525100
Emerson Lorain A2F50 58824700002
Emerson Lorain A50B50 486522200
Emerson Lorain 433800216 Alarm Board
Emerson Lorain 486800127 MHSA10B DC-DC Converter Module 24 to -48V 10 Amp
Emerson Lorain MZ10F50 486521600
Emerson Lorain MZHSA3B 486884600
Emerson Lorain 433800219 Meter Card
Emerson Lorain R48-5800 —
Emerson Lorain 4865-145 Regulator & Alarm Card
Emerson Lorain V100B25 Rectifier 486529600
Emerson Lorain V130B25 Rectifier 486531902
Emerson Lorain V150/180B25 Rectifier 486534100
Emerson Lorain V15F50/P 486530400
Emerson Lorain V200E50 486531000
Emerson Lorain V25B50 486530300
Emerson Lorain V50B50 486529900
Emerson Lorain Marconi V100B25 Rectifier 486529601
Emerson Lorain Marconi V130B25 Rectifier 486531900
Emerson Lorain Vortex V65B50 486531800
Emerson Lorain Vortex V85/105B50 486533900
Emerson Lorian V200D50 486527801
Emerson Lorian V50B50 486529902
Emerson Lorian Marconi Vortex V30F25/P 486529500
Delta Electronics ESR-24/100BA 24VDC/100 amp rectifier module
Delta Electronics ESR-24/100E A-S 25 VDC/100-amp rectifier for HDS plant
Delta Electronics ESR-48/150A —
Delta Electronics ESR-48/50B —
Delta Electronics ESR-48/56B —
Delta Electronics ESR-24/100AA rectifier
C&D Technologies HFM24BC150 100-7520-24A - 24V/150A Rectifier
Ciena 130-2425-910 —
Ciena 130-2426-910 —
Ciena 130-2427-910 —
Datum 23413019-000-0 GPS input module 8v grouped assets
Eaton APR48 Series —
Eaton APR48-3G —
Exalt E240101 Ethernet unlicenseed point to point microwave radio
Exeltech MX control card —
Exeltech MX1000 power inverter —
Exeltech Transfer Switch —
Hawker 6LA20671 —
Invensys / Eaton / Switchtec R2948 —
M.G.E. (owned by Eaton) Topaz S3 72-153068
Nortel (owned by Ciena) NTHW31AB 16 port oc3 atm function processor
Nortel (owned by Ciena) NT5C05CE —
Nortel (owned by Ciena) NT5C05CE-46 —
Nortel (owned by Ciena) NT5C05DB —
Nortel (owned by Ciena) NT5C05DC —
Nortel (owned by Ciena) NT5C05DD —
Nortel (owned by Ciena) NTN410CA —
Symmetricom 23413016-000-0 Stratum 2E RB Clock
TDI (Transdev Electronics) MER12WRB-N48D00 09004-136874-N48D00
TPS 128981-2 DC/DC Converter 52V/10A
Rectifier Technologies RT8-48V/50A 48V 50A Rectifier

Don’t see your part number? This list covers the parts we see most, not everything we repair. Send us the part number from the module label and we will confirm.

Send Us Your Part Number

How Rectifier Repair Works

  1. Send Us the Part Number

    Use the Customer Repair Form or call (800) 323-4813 with the part number, the quantity and what the module is doing.

  2. Confirmation and Quote

    We confirm we repair it and quote the job before any work begins.

  3. Ship It to Our Depot

    You receive an RMA number and send the modules to our depot in Glendale Heights, Illinois.

  4. Repaired, Tested, Returned

    Component-level repair or refurbishment, then full functional testing. Most repairs return in 1–2 weeks with a 1-year warranty.

Rectifier Families We Repair

Most DC plants run one manufacturer’s modules, often under an older brand name. Here is what we see most from each, and every part number is in the searchable list above.

Valere rectifier repair

The largest group on this page, with 180 Valere part numbers: the V-Series and V-Series HE, the H Series and the J Series, including V1250, V2500, H1250, H2500 and J1500 models. Valere became part of Eltek, and we repair both lines.

Alpha, Argus and Cordex rectifier repair

Alpha Technologies and Argus Technologies equipment, from Cordex rectifier modules (010-5xx and 010-6xx part numbers, including the 48V 3.6kW) to RST and RSM rectifiers, Pathfinder power modules, and Cordex CXCM controllers, DC-DC converters and shelves.

GE, Lineage, OmniOn, Tyco and Lucent rectifier repair

One product line under several names over the years. We repair the 595 Galaxy rectifiers (595A, 595A2, 595A3, 595B2, 595B3), the 595LTA and 595LTB, the 596 series, Infinity rectifiers such as the NE050AC48ATEZ and NE075AC48ATEZ, Peco II SM rectifiers, and Alcatel-Lucent ES460C, ES660C and ES661C units.

Emerson and Vertiv NetSure rectifier repair

Emerson Network Power (now Vertiv) rectifiers, including NetSure R48-3200 modules and the LPS200 series, the R48-5800, and legacy Lorain, Vortex, Astec Helios and Candeo units such as the A50B50, V50B50, V65B50 and V100B25.

Delta rectifier repair

Delta Electronics ESR-48 and ESR-24 rectifiers, including the ESR-48/50B, ESR-48/56B and ESR-48/150A. Delta is now Eltek’s parent company.

Eaton, C&D and other telecom power

Eaton APR48 rectifiers, C&D Technologies HFM24 rectifiers, Exeltech MX inverters, Hawker, TDI and Invensys units, Rectifier Technologies RT8-48V/50A rectifiers, plus telecom power, timing and interface modules from Nortel, Ciena, Symmetricom and Datum.

Repair, Replace or Go Back to the Manufacturer?

A failed module in a working DC plant is a common situation, and the right answer depends on where the module sits in its life. Here is the short version.

  • Still under the manufacturer’s warranty

    If the module is new enough to be covered, the manufacturer should be paying for the fix.

    Go to the manufacturer.

  • The manufacturer still repairs it

    Some lines are still supported by the OEM. It is worth having a second quote to compare on price and turnaround.

    Get our quote alongside theirs.

  • The manufacturer has moved on

    Legacy and rebranded lines, such as GE, Lineage and OmniOn, or Eltek products no longer supported since 2020, keep running in plants long after OEM repair ends. The plant is sound; the module needs a bench.

    Talk to us.

  • Failed spares sitting on a shelf

    Modules pulled from service over time are recoverable inventory. Send the batch with one repair request and get them back as working spares.

    Talk to us.

Common Rectifier Faults We Repair

Switchmode rectifiers tend to fail in a handful of recognizable ways. Tell us which one you are seeing when you send the part number. It speeds up the quote.

Fail or alarm light, no DC output

The module powers up, raises an alarm and delivers nothing to the bus, or it stays dark altogether. This usually points to a failure in the power stage and is a bench repair.

Fan failure or over-temperature shutdown

Rectifiers depend on their fans. A worn fan lets the module run hot, derate and then shut down. Caught early, a fan fault is one of the simpler repairs.

Will not share load, or low output

A module that stays online but carries less than its share of the load, or sits below the plant’s float voltage, is working harder than its neighbors and should be pulled for testing.

Intermittent shutdowns and restarts

Modules that drop out and recover on their own are hard to diagnose in the field. On the bench they can be run under load until the fault shows itself.

Not recognized by the controller

If the controller cannot see or address a module, the fault can be in the module’s communication circuit or its connector. Send the controller model along with the part number.

Who We Support

DC power plants run far more than the telephone network. We repair rectifiers for:

Rectifier Repair: Frequently Asked Questions

Which rectifier brands do you repair?

We repair DC plant switchmode rectifiers from Eltek, Valere, Alpha, Argus and Cordex, Alcatel-Lucent, GE, Lineage Power and OmniOn (including the 595 series), Emerson and Vertiv NetSure, Delta Electronics, Tyco, Peco II, Eaton and others. The searchable list on this page covers more than 450 part numbers. If yours is not listed, send us the part number and we will confirm.

Do you still repair Eltek rectifiers that Eltek no longer supports?

Yes. As of August 2020, Eltek (a Delta company) is no longer supporting the repairs of a number of its parts and products. As Eltek's North American Depot Repair Center for over 20 years, ATS has been authorized to continue to service these parts outside of Eltek's operations.

How long does a rectifier repair take?

ATS' typical repair turnaround time is approximately 1-2 weeks on most repairs. If you have a larger batch or a deadline, tell us when you request the quote.

What warranty comes with a repaired rectifier?

The ATS warranty on most repair services is 1 year from the date of the service.

My part number is not on the list. Can you still repair it?

Often, yes. The list covers the part numbers we see most, not everything we repair. Send us the part number from the module label, the quantity and what the unit is doing, and we will tell you whether we can repair it.

How do I send a rectifier in for repair?

Fill out the Customer Repair Form with the part number, quantity and the fault, or call (800) 323-4813. We confirm the repair and quote it, issue an RMA number, and you ship the modules to our depot in Glendale Heights, Illinois.

Do you repair controllers and converters as well as rectifiers?

Yes. Alongside rectifier modules, the list includes DC plant controllers, supervisory panels and DC-DC converters from the same manufacturers. For whole-plant needs, see our DC Plant Support Services.

Do you refurbish rectifiers as well as repair them?

Yes. ATS repairs and remanufactures telecom rectifiers, with over 40 years of experience supporting OEM products. Whether a module needs a single component repair or a full refurbishment, we quote it before any work begins, and every unit is functionally tested before it ships back.

Is Advanced Technical Services ISO certified?

Yes. ATS holds a current ISO 9001:2015 certification and is audited to current quality standards every year by an independent quality auditing company.

Get Your Rectifiers Back in Service

Send us the part number and we will confirm the repair and quote it.

Speak to an ATS Representative About Your Needs Today

CONTACT ATS >>